]> review.fuel-infra Code Review - openstack-build/cinder-build.git/commit
3PAR use same LUN id for each export path
authorWalter A. Boring IV <walter.boring@hpe.com>
Tue, 1 Mar 2016 15:22:21 +0000 (07:22 -0800)
committerWalter A. Boring IV <walter.boring@hpe.com>
Thu, 3 Mar 2016 13:19:31 +0000 (05:19 -0800)
commitf813bde3c5b2ec357a51b8172db64e31a967cc35
treef973c0eb9a19d4e39dd0898297796d8ec2fdea09
parent6fa468270c670a80829066ad2b811b61e5c2ab98
3PAR use same LUN id for each export path

When multipath is enabled, and the 3PAR driver is configured
to export a VLUN over N iSCSI IP(ports), we now use the same
LUN ID for each iSCSI IP export.  Previously, when we would
export a volume over N iSCSI ports, we would get a new LUN ID
for each iSCSI port.

Change-Id: Ide0ce373a14f348a554688dee9b699feed3c5f26
Closes-Bug: #1551994
cinder/tests/unit/test_hpe3par.py
cinder/volume/drivers/hpe/hpe_3par_common.py
cinder/volume/drivers/hpe/hpe_3par_iscsi.py